Skip to main content

ALAMO user manual and installation guide v. 2021.5.8

Welcome, Anonymous

pdf-html

ALAMO user manual and installation guide v. 2021.5.8

May 8, 2021

For information about this software, contact Nick Sahinidis at niksah@minlp.com.

Contents

1

Introduction

1

1.1Licensing and software requirements . . . . . . . . . . . . . . . . . . . . 2

1.2Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2Algorithms implemented . . . . . . . . . . . . . . . . . . . . . . . . . . 3

3 Running ALAMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

3.1

Running the interactive GUI . . . . . . . . . . . . . . . . . . . . . . . . 3

3.2Running ALAMO from the command line . . . . . . . . . . . . . . . . . 4

4 Example input file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 5 Input file grammar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 6 ALAMO data and options specification statements . . . . . . . . . . 6

6.1Required scalar parameters . . . . . . . . . . . . . . . . . . . . . . . . . 6

6.2Required vector parameters . . . . . . . . . . . . . . . . . . . . . . . . . 6

6.3Optional data specifications . . . . . . . . . . . . . . . . . . . . . . . . . 7

6.4Constrained regression . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

7ALAMO output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

7.1ALAMO screen output . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

8Termination conditions and error messages . . . . . . . . . . . . . . . 23

9 Compatibility with previous versions of ALAMO . . . . . . . . . . . 29

10 Bibliography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

1Introduction

The purpose of ALAMO (Automatic Learning of Algebraic MOdels) is to generate algebraic surrogate models of black-box systems for which a simulator or experimental setup is available.

2

ALAMO user manual and installation guide v. 2021.5.8

 

 

Consider a system for which the outputs z are an unknown function f of the system inputs x. The software identifies a function f , i.e., a relationship between the inputs and outputs of the system, that best matches data (pairs of x and corresponding z values) that are collected via simulation or experimentation. ALAMO can:

•build an algebraic model of a simulation or experimental black-box system

•use previously collected data for model building

•call a user-specified function (simulator) to collect measurements

•enforce response variable bounds, physical limits, and boundary conditions

•use a preexisting data set for model validation

•output models in simple algebraic form

The problems addressed by the software have long been studied in the fields of statistics, design of experiments, and machine learning. Whereas existing techniques from this literature can be used to fit data to models, the main challenges addressed by the ALAMO software are in determining where to run the simulations or experiments, what models to fit, and how to determine if the model is accurate and as simple as possible. A distinguishing feature of ALAMO is that it provides models that are accurate yet as simple as possible. Moreover, ALAMO is capable of utilizing theory-driven insights alongside data. The ALAMO models can be used to facilitate subsequent system analysis, optimization, and decision making.

1.1Licensing and software requirements

The code is available for download at http://minlp.com/alamo. The same URL provides infor- mation about licensing the software. Under certain algorithmic options, especially for constrained regression, ALAMO makes calls to the third party software GAMS. If the user intends to apply ALAMO’s constrained regression capability, a separate install and license are required for GAMS and at least one of the mixed-integer quadratic programming solvers under GAMS, preferably GAMS/BARON. More information about GAMS can be found at http://www.gams.com. In the absence of a GAMS license, ALAMO attempts to use enumerative approaches that may be more time consuming or impractical for large problems. For constrained regression only, GAMS/BARON is required.

1.2Installation

Install ALAMO and the ALAMO license file in any directory of your choice and add it to your path. On Windows, ALAMO’s installer will take care of these steps for you. On Linux and OSX systems, unzip the ALAMO download and place the files it contains in a directory in your path. Users should not open the license file in an editor as this may invalidate the license in certain operating systems. For all operating systems, make sure that ALAMO and the ALAMO license file are readable by all intended users on your machine. Do the same for GAMS. Installation of GAMS is optional but recommended.

ALAMO user manual and installation guide v. 2021.5.8

3

 

 

2Algorithms implemented

ALAMO seeks to identify low-complexity surrogate models using a minimal amount of data for a system that is described by a simulator or experiment. Surrogate models are constructed using a three-step process. In the first step, an initial design of experiments is generated and the simulation is queried at these points. In the second step, an algebraic model is built using this initial training set. The model is built using integer optimization techniques to select the best subset from a collection of potential sets of basis functions that can be used to build up the model. In the third step, an adaptive sampling methodology based on derivative-free optimization techniques is used to identify points where the model is inaccurate. Once these points are added to the training set, execution returns to the second step of the algorithm. The process continues until the third step confirms the accuracy of a previously built model.

Compared to common techniques, such as forward- or backward-regression, that investigate model sensitivities with respect to one basis function at a time, ALAMO’s best subset selection techniques ensure that its model-building steps account for the synergistic effects between differ- ent basis functions. Before ALAMO, best subset selection techniques were considered too time consuming for application to realistic data sets. While developing ALAMO, nonlinear integer programming techniques were devised that rely on the BARON software to solve these models in realistic computing times for many industrially relevant systems. ALAMO is also unique in that it utilizes derivative-free optimization techniques in its adaptive sampling step. These techniques offer a systematic approach to interrogate models, identify weaknesses, and guide experimental design towards parts of the space requiring more attention. Another distinctive feature of ALAMO is its constrained regression feature, which is capable of enforcing theory- driven requirements on response variables, including response variable bounds, thermodynamic limitations, and boundary conditions. To enforce these requirements over the entire domain of input variables, ALAMO relies on BARON to solve semi-infinite nonconvex optimization prob- lems.

The bibliography at the end of this document offers more details of the methodology implemented in ALAMO and demonstrates the advantages of this methodology in comparison to currently utilized approaches, including classical regression and the lasso.

3Running ALAMO

3.1Running the interactive GUI

The ALAMO GUI allows for a convenient spreadsheet-style input of problem data and algorith- mic options, and offers facilities for visualizing the data and results, and saving your work. On all operating systems, Java is required in order to use the ALAMO GUI. Additionally, the user must have write privileges in the directory where the GUI is invoked.

On Windows systems, the installer will create an ALAMO icon on your desktop. Double click at this icon in order to launch ALAMO’s interactive GUI.

On Linux and OSX, the interactive GUI is available in the download directory and named alamogui.jar. To run this, open a terminal and type the following command at the prompt

4

ALAMO user manual and installation guide v. 2021.5.8

 

 

java -jar alamogui.jar

On all systems, the GUI allows you to save the model input data in the form of an ALAMO file that can be read later by the GUI. After running ALAMO, the results can be saved in an ALAMO listing file that can also be read later by the GUI to reconstruct the problem inputs and results.

Even if you are not planning to use ALAMO from the command line, you should still plan to quickly read the next subsection and following section as they explain how ALAMO works and what is expected to make it run correctly. Additionally, these sections describe material related to algorithmic options that are available in a very similar format through the GUI.

3.2Running ALAMO from the command line

As an alterative to using the GUI, users can utilize ALAMO form the command line. ALAMO reads model data and algorithmic options from a text file in a simple format. Even though it is not required, it is strongly recommended that all ALAMO input files have the extension ‘.alm.’ If the input file is named ‘test.alm’ and the ALAMO executable is named ‘alamo,’ issuing the command

alamo test

or

alamo test.alm

results in ALAMO parsing test.alm and solving the problem. In addition to screen displays, ALAMO can also provide results in the listing file ‘test.lst’ that is generated during the run. The

.lst file is always stored in the execute directory, even when the .alm file is in a different path. During execution, ALAMO creates and utilizes a directory for storing various work files. When calling ALAMO, the user may optionally include a second command line argument in order to specify ALAMO’s working directory:

alamo test.alm myscratchdir

where ‘myscratchdir’ denotes the name of ALAMO’s scratch directory. If this argument is not specified, ALAMO will create and utilize a directory named ‘almscr’ in the execute directory. If the scratch exists, it is erased in the beginning of the run. At the end of the run, ALAMO will delete its scratch directory.

4Example input file

The following file is referred to as ‘e1.alm’ and pertains to learning the simple function z = x2. There is one input and one output in the model. The input is restricted between −5 and 5. An initial sampling data set is specified and is comprised of 11 preexisting data points. The user

ALAMO user manual and installation guide v. 2021.5.8

5

 

 

options do not call for adaptive sampling to be used, effectively requesting the best possible model that can be derived from the preexisting data set. Finally, the following functions are permitted in the model: linear, logarithmic, exponential, sine, cosine, and monomials with powers 2 and 3.

!Example 1 with data from z = x^2 ninputs 1

noutputs 1 xmin -5 xmax 5

ndata 11

linfcns 1 logfcns 1 expfcns 1 sinfcns 1 cosfcns 1 monomialpower 2 3

BEGIN_DATA

-5

25

-4

16

-3

9

-2

4

-1

1

00

11

24

39

416

525

END_DATA

Several additional examples of ALAMO input files accompany the distributed code.

5Input file grammar

The following rules should be followed when preparing an ALAMO input file:

•The name of the input file should include its exact path location if the file is not present in the execute directory.

•The name of the input file should not exceed 1000 characters in length.

•The input is not case sensitive.

6

ALAMO user manual and installation guide v. 2021.5.8

 

 

•Most options are entered one per line, in the form of ‘keyword’ followed by ‘value’. Certain vector options are entered in multiple lines, starting with ‘BEGIN <keyword>’, followed by the vector input, followed by ‘END <keyword>’.

•Certain options must appear first in the input file. This requirement is discussed explicitly in option descriptions provided below.

•With the exception of arguments involving paths, character-valued options should not contain spaces.

•Blank lines, white space, and lines beginning with *, #, % or ! are skipped. Inline comments that are preceded by #, % or ! are permitted in any line that contains alphanumeric options. Blocks of comment lines are allowed using ‘BEGIN COMMENT’, followed by the block of comment lines, followed by ‘END COMMENT’; these comment blocks are entirely ignored by ALAMO.

6ALAMO data and options specification statements

6.1Required scalar parameters

The following parameters must be specified in the input file in the order listed below.

Parameter

Description

 

 

NINPUTS

Number of model input variables. NINPUTS must be a

 

positive integer and defines the dimension of the vector x.

NOUTPUTS

Number of model output variables. NOUTPUTS must be

 

a positive integer and defines the dimension of the vector

z.

6.2Required vector parameters

The following parameters must be specified in the input file in the order listed below and only after the scalar required parameters have already been specified.

Parameter

Description

 

 

XMIN

Row vector specifying minimum values for each of the in-

 

put variables. This should contain exactly NINPUTS en-

 

tries that are space delimited.

 

 

XMAX

Row vector specifying maximum values for each of the

 

input variables. This should contain exactly NINPUTS

 

entries that are space delimited.

 

 

XMIN and XMAX do not necessarily correspond to the minimum and maximum values of the data provided by the user to ALAMO. Instead, they should reflect the physically meaningful lower and upper bounds for the input variables. These values are used by ALAMO for scaling

ALAMO user manual and installation guide v. 2021.5.8

7

 

 

purposes as well as for generating samples when no preexisting data set is provided or, in general, when adaptive sampling is done.

6.3Optional data specifications

This section describes optional parameters pertaining to the particular problem being solved.

Option

Description

Default

 

 

 

NDATA

Number of data points in a preexisting data set specified

0

 

by the user. NDATA must be a nonnegative integer.

 

NPREDATA

Number of data points for which ALAMO will provide

0

 

predictions to the user. At the end of the run, ALAMO

 

 

will calculate predictions using its best model at each of

 

 

the NPREDATA data points. NPREDATA must be a

 

 

nonnegative integer.

 

 

 

 

NSAMPLE

Number of data points to be generated by sampling before

0

 

any model is built. These points will be used for model

 

 

building along with the NDATA points specified by the

 

 

user. NSAMPLE must be a nonnegative integer.

 

 

 

 

NVALSETS

Number of data sets to be used for validation after model

0

 

generation. Validation of the model will be performed on

 

 

each data set separately. NVALSETS must be a nonneg-

 

 

ative integer.

 

NVALDATA

Number of preexisting data points in each of the

0 0 0 . . .

 

NVALSETS data sets. These data points are not used

 

 

to develop the model but only to compute model errors at

 

 

the validation data points. NVALDATA must be an array

 

 

of NVALSETS nonnegative integers. If NVALDATA is

 

 

provided and NVALSETS has not already been specified

 

 

in the input file, ALAMO will assume that NVALSETS

 

 

equals 1.

 

 

 

 

NVALSAMPLE

Number of data points to be sampled and added to each

0 0 0 . . .

 

of the NVALSETS data sets for validation. These data

 

 

points are not used to develop the model but only to com-

 

pute model errors at the validation data points. NVAL- SAMPLE points are sampled randomly and added to the validation data sets. The sampling facility requires that the user provides a SIMULATOR. Validation can rely ex- clusively on preexisting data (through the NVALDATA option), exclusively on sampled data (through the NVAL- SAMPLE option), or on any combination desired by the user. NVALSAMPLE must be an array of NVALSETS nonnegative integers. If NVALSAMPLE is provided and NVALSETS has not already been specified in the input file, ALAMO will assume that NVALSETS equals 1.

8

ALAMO user manual and installation guide v. 2021.5.8

 

 

MAXSIM

Maximum number of successive simulator failures allowed

0

 

 

before we quit. MAXSIM must be a non-negative integer.

 

 

 

If MAXSIM equals 0, ALAMO will continue calling the

 

 

 

simulator even in the case of repeated failures.

 

 

 

 

 

 

MINPOINTS

At any stage of the adaptive sampling process, conver-

NINPUTS

 

gence is assessed only if the simulator is able to compute

 

 

 

the output variables for at least MINPOINTS out of the

 

 

 

data points requested by ALAMO. MINPOINTS must be

 

 

 

a positive integer.

 

 

 

 

 

 

MAXPOINTS

The number of data points requested by ALAMO from the

NINPUTS+6

 

simulator during an adaptive sampling iteration. MAX-

 

 

 

POINTS must be a positive integer at least as large as

 

 

 

MINPOINTS.

 

 

XFACTOR

Row vector of scaling factors used to scale the input vari-

1 1 1 . . .

 

 

ables. One per input variable, space separated.

 

 

XSCALING

A 0−1 indicator. If 1 and XFACTORS are not provided

0

 

 

in the input file, ALAMO sets XFACTORS equal to the

 

 

 

range of each input variable.

 

 

 

 

 

 

SCALEZ

A 0−1 indicator. If 1, outputs are scaled when solving

0

 

 

mixed-integer optimization problems; otherwise, they are

 

 

 

not scaled.

 

 

 

 

 

 

XLABELS

Row vector of labels to denote the input variables. One

X1 X2 X3

. . .

 

 

per input variable, space separated. Each label can be no

 

 

 

 

 

more than 128 characters long. All labels must begin with

 

 

 

an alphabetical character (A-Z or a-z) and contain only

 

 

 

alphanumerical characters (A-Z, a-z, 0-9) or underscores.

 

 

ZLABELS

Row vector of labels to denote the output variables. One

Z1 Z2 Z3

. . .

 

 

per output variable, space separated. Each label can be no

 

 

 

 

 

more than 128 characters long. All labels must begin with

 

 

 

an alphabetical character (A-Z or a-z) and contain only

 

 

 

alphanumerical characters (A-Z, a-z, 0-9) or underscores.

 

 

 

 

 

 

MONO

Number of monomial powers to be considered as basis

0

 

 

functions. MONO must be a nonnegative integer.

 

 

 

 

 

 

MULTI2

Number of powers to be considered for pairwise combina-

0

 

 

tions of basis functions. MULTI2 must be a nonnegative

 

 

 

integer.

 

 

 

 

 

 

MULTI3

Number of powers to be considered for three variable com-

0

 

 

binations of basis functions. MULTI3 must be a nonneg-

 

 

 

ative integer.

 

 

RATIOS

Number of ratio combinations of powers to be considered

0

 

 

as basis functions. RATIOS must be a nonnegative inte-

 

 

 

ger.

 

 

 

 

 

 

EXPFCNS

A 0−1 indicator. Exponential functions are considered as

0

 

 

basis functions if 1; otherwise, they are not considered.

 

 

 

 

 

 

ALAMO user manual and installation guide v. 2021.5.8

9

 

 

LINFCNS

A 0−1 indicator. Linear functions are considered as basis

1

 

functions if 1; otherwise, they are not considered.

 

LOGFCNS

A 0−1 indicator. Logarithmic functions are considered as

0

 

basis functions if 1; otherwise, they are not considered.

 

 

Natural logarithms are used.

 

 

 

 

 

 

 

 

SINFCNS

A 0−1 indicator. Sine functions are considered as basis

0

 

functions if 1; otherwise, they are not considered. The

 

 

arguments of these functions are assumed in radians.

 

 

 

 

 

 

 

 

COSFCNS

A 0−1 indicator. Cosine functions are considered as basis

0

 

functions if 1; otherwise, they are not considered. The

 

 

arguments of these functions are assumed in radians.

 

 

 

 

 

 

 

 

CONSTANT

A 0−1 indicator. A constant will be considered as a basis

1

 

function if 1; otherwise, it will not be considered.

 

NCUSTOMBAS

Number of user-specified basis functions. NCUSTOMBAS

0

 

must be a nonnegative integer. If this option is utilized,

 

 

then a BEGIN

 

CUSTOMBAS ... END

 

CUSTOMBAS

 

 

section must be supplied to provide the algebraic expres-

 

 

sions of the user-specified basis functions.

 

 

 

 

GRBFCNS

A 0−1 indicator. Gaussian radial basis functions centered

0

 

around the set of the user-specified NDATA points are

 

 

considered as basis functions if 1; otherwise, they are not

 

 

considered. These functions are deactivated if their tex-

 

 

tual representation requires more than 128 characters (in

 

 

the case of too many input variables and/or data points).

 

 

 

 

RBFPARAM

Multiplicative constant used in the Gaussian radial basis

1.0

 

functions.

 

TRACE

A 0−1 indicator. If set to 1, a trace file is generated at

0

 

the end of the run, including a succinct summary of the

 

 

results. First, a header line beginning with a # is printed

 

 

describing the contents of each line of the trace file. Then,

 

 

for each output, results are printed in one line for each

 

 

data set. Data sets are marked by the numbers 0 (observed

 

 

data set), -1 (user-provided validation data set), and 1, ...,

 

 

NVALSETS (ALAMO-generated validation sets).

 

 

 

 

TRACEFNAME

Name of trace file. Summaries are appended to an existing

trace.trc

 

trace file.

 

 

 

 

 

 

 

 

10

ALAMO user manual and installation guide v. 2021.5.8

 

 

MODELER

Fitness metric to be used for model building. Possible

1

 

values are 1 through 8, with the following meaning:

 

 

1. BIC: Bayesian information criterion,

 

 

2. Cp: Mallow’s Cp,

 

 

3. AICc: the corrected Akaike’s information criterion,

 

 

4. HQC: the Hannan-Quinn information criterion,

 

 

5. MSE: mean square error,

 

 

6. SSEp: the sum of square errors plus a penalty pro-

 

 

portional to model size,

 

 

7. RIC: the risk information criterion, and

 

 

8. MADp: the maximum absolute deviation plus a

 

 

penalty proportional to model size. The deviation is

 

 

expressed as absolute percent deviation from mea-

 

 

surements that exceed 10−3 in magnitude and as an

 

 

absolute difference for small measurements.

 

 

 

 

BUILDER

A 0−1 indicator. If set to 1, a greedy heuristic builds up

1

 

a model by adding one variable at a time. This model is

 

 

used as a starting point for solving an integer programming

 

 

formulation according to the choice of MODELER. If an

 

 

optimizer is not available, the heuristic model will be the

 

 

final model to be returned.

 

 

 

 

BACKSTEPPER

A 0−1 indicator. If set to 1, a greedy heuristic builds

0

 

down a model by starting from the least squares model

 

 

and removing one variable at a time.

 

CONVPEN

When MODELER is set to 6 or 8, a penalty consisting

0.0

 

of the sum of square errors (MODELER=6) or the maxi-

 

 

mum absolute error (MODELER=8) and a term penaliz-

 

 

ing model size is used for model building. The size of the

 

 

model is weighted by CONVPEN. If CONVPEN=0, this

 

 

metric reduces to the classical sum of square errors (MOD-

 

 

ELER=6) or the maximum absolute deviation (MOD-

 

 

ELER=8).

 

 

 

 

SCREENER

Screening method used to reduce the number of potential

0

 

basis functions before optimization of the selected fitness

 

 

metric. Possible values are 0, 1, and 2, corresponding to no

 

 

screening, screening with the lasso, and sure independence

 

 

screening, respectively.

 

 

 

 

NCVF

Number of folds to be used for cross validation by the

5

 

lasso screener. ALAMO will use a two-fold validation if

 

 

fewer than 10 data points are available. NCVF must be a

 

 

nonnegative integer.

 

ALAMO user manual and installation guide v. 2021.5.8

11

 

 

SISmult

This parameter must be non-negative and is used to de-

1

 

termine the number of basis functions retained by the SIS

 

 

screener. The number of basis functions retained equals

 

 

the floor of SSISmult LN(N) , where n is the number of mea-

 

 

 

N

 

 

surements available at the current ALAMO iteration.

 

 

 

 

INITIALIZER

Technique to be used for sampling of the NSAMPLE

1

 

points (or INITIALPOINTS minus NDATA) at the be-

 

 

ginning of the algorithm. A nonzero value of NSAM-

 

 

PLE directs ALAMO to use sampling according to the

 

 

value of INITIALIZER and requires the presence of a

 

 

user-provided SIMULATOR. Possible INITIALIZER val-

 

 

ues are: 1 (random); 3 (Faure). INITIALPOINTS is de-

 

 

scribed in Section 9.

 

 

 

 

SAMPLER

Technique to be used for adaptive sampling. A value of

1

 

MAXITER different than 1 directs ALAMO to use adap-

 

 

tive sampling according to the value of SAMPLER and

 

 

requires the presence of a user-provided SIMULATOR.

 

Possible SAMPLER values are: 1 (random), 2 (SNOB-

FIT), 3 (Faure).

12

ALAMO user manual and installation guide v. 2021.5.8

 

 

SIMULATOR

SIMULATOR is the name of the executable that ALAMO

mysim

 

can call in order to obtain function evaluations of the

 

 

black box. The simulator must be able to read file SIMIN

 

 

and write file SIMOUT. SIMIN is provided by ALAMO.

 

 

The first line of SIMIN provides the number of requested

 

 

data points, k, followed by pid, an integer that provides

 

 

the process id of the current ALAMO process that gen-

 

 

erated SIMIN. After this first line, there are k additional

 

 

lines, one for each of the data points where function eval-

 

 

uations are requested. Following these lines, a single

 

 

line contains NOUTPUTS T/F (true/false) flags indicated

 

 

whether ALAMO is requesting a simulation of each cor-

 

 

responding output variable; the simulator may choose to

 

 

ignore this information or utilize it in order to avoid simu-

 

 

lation of outputs for which this flag is F. In SIMOUT, the

 

 

simulator must return a number of lines, each containing

 

 

a point in the input variable space where a simulation was

 

 

performed, along with the corresponding output variable

 

 

values. ALAMO allows for the number of these points to

 

 

be different than k and for these points to be different than

 

 

the points where simulations were requested. If more than

 

 

k points are provided, only the first k are used. If the sim-

 

 

ulation fails or is impossible for certain output variables,

 

 

partial simulation results may be returned and the non-

 

 

available output variables must be set equal to PRESET.

 

 

The simulator must be in the directory where ALAMO is

 

 

launched or in the user’s path; alternatively, its complete

 

 

path must be specified through this option. ALAMO will

 

 

execute the simulator in a scratch directory it generates

 

 

during its run; hence, the simulator should not rely on any

 

 

relative paths in order to access other programs or files.

 

 

The simulator may utilize pid in order to halt and resume

 

 

the execution of ALAMO. For instance, in Linux, this can

 

 

be achieved with the commands ‘kill -TSTP pid’ and ‘kill

 

 

-CONT pid’; additionally, checkpointing can be used to

 

 

save all program information in case a system reboot takes

 

 

place while waiting for the simulator to complete.

 

PRESET

A value indicating that the simulator was not able to com-

-111111.

 

pute a specific output variable at a specific point. This

 

 

value must be carefully chosen to be an otherwise not re-

 

 

alizable value for the output variables.

 

 

 

 

MAXTIME

Maximum total execution time allowed in seconds. This

1000

 

time includes all steps of the algorithm, including time

 

to read problem, preprocess data, solve optimization sub- problems, and print results.

ALAMO user manual and installation guide v. 2021.5.8

13

 

 

 

MAXITER

Maximum number of ALAMO iterations. Each iteration

1

 

 

begins with a model-building step. An adaptive sampling

 

 

 

step follows if MAXITER does not equal 1. If MAXITER

 

 

 

is set to a number less than or equal to 0, ALAMO will

 

 

 

enforce no limit on the number of iterations.

 

 

 

 

 

DATALIMITTERMS A 0−1 indicator. If 1, ALAMO will limit the number of

1

 

 

terms in the model to be no more than the number of data

 

 

 

measurements; otherwise, no limit based on the number of

 

 

 

data measurements will be placed. The user may provide

 

 

 

an additional limit on the number of terms in the model

 

 

 

through the MAXTERMS and MINTERMS options.

 

 

MAXTERMS

Row vector of maximum terms allowed in the modeling

-1 -1 -1

 

. . .

 

 

of output variables. One per output variable, space sepa-

 

 

 

 

 

rated. A −1 signals that no limit is imposed.

 

 

 

 

 

 

MINTERMS

Row vector of minimum terms required in the modeling

0 0 0 . . .

 

 

of output variables. One per output variable, space sepa-

 

 

 

rated. A 0 signals that no limit is imposed.

 

 

NUMLIMITBASIS

A 0−1 indicator. If 1, ALAMO will eliminate basis func-

1

 

 

tions that are not numerically acceptable (e.g., log(x) will

 

 

 

be eliminated if x may be negative; otherwise, no limit

 

 

 

based on the number of data measurements will be placed.

 

 

 

The user may provide additional limits on the the type

 

 

 

and number of selected basis functions through the op-

 

 

 

tions EXCLUDE and GROUPCON.

 

 

 

 

 

 

EXCLUDE

Row vector of 0/1 flags that specify which input variables,

0 0 0 . . .

 

 

if any, ALAMO should exclude during the model building

 

 

 

process. All input variables must be present in the data

 

 

 

but ALAMO will not include basis functions that involve

 

 

 

input variables for which EXCLUDE equals 1. This fea-

 

 

 

ture does not apply to custom basis functions or RBFs.

 

 

 

 

 

 

IGNORE

Row vector of 0/1 flags that specify which output vari-

0 0 0 . . .

 

 

ables, if any, ALAMO should ignore. All output variables

 

 

 

must be present in the data but ALAMO does not model

 

 

 

output variables for which IGNORE equals 1.

 

 

XISINT

Row vector of 0/1 flags that specify which input variables,

0 0 0 . . .

 

 

if any, ALAMO should treat as integers. For integer in-

 

 

 

puts, ALAMO’s sampling will be restricted to integer val-

 

 

 

ues.

 

 

 

 

 

 

ZISINT

Row vector of 0/1 flags that specify which output vari-

0 0 0 . . .

 

 

ables, if any, ALAMO should treat as integers. For inte-

 

ger variables, ALAMO’s model will include the rounding of a function to the nearest integer (equivalent to the nint function in Fortran.)

14

ALAMO user manual and installation guide v. 2021.5.8

 

 

 

TOLRELMETRIC

Relative convergence tolerance for the chosen fitness met-

1e-6 1e-6

 

1e-6 . . .

 

 

ric for the modeling of output variables. One per output

 

 

 

 

 

variable, space separated. Incremental model building will

 

 

 

stop if two consecutive iterations do not improve the cho-

 

 

 

sen metric by at least this amount.

 

 

 

 

 

 

TOLABSMETRIC

Absolute convergence tolerance for the chosen fitness met-

1e-6 1e-6

 

1e-6 . . .

 

 

ric for the modeling of output variables. One per output

 

 

 

 

 

variable, space separated. Incremental model building will

 

 

 

stop if two consecutive iterations do not improve the cho-

 

 

 

sen metric by at least this amount.

 

 

TOLMEANERROR

Row vector of convergence tolerances for mean errors in

0 0 0 . . .

 

 

the modeling of output variables. One per output vari-

 

 

 

able, space separated. Incremental model building will

 

 

 

stop if TOLMEANERROR, TOLRELMETRIC, or TO-

 

 

 

LABSMETRIC is satisfied.

 

 

 

 

 

 

TOLMAXERROR

Absolute tolerance for the adaptive sampling procedure

0.05 0.05

 

0.05 . . .

 

 

to terminate during the modeling of output variables.

 

 

 

 

 

One per output variable, space separated. Adaptive sam-

 

 

 

pling will stop if the current model predictions and mea-

 

 

 

surements do not differ in magnitude by more than this

 

 

 

amount.

 

 

 

 

 

 

TOLSSE

Absolute tolerance on sum of square errors (SSE).

0

 

 

ALAMO will terminate if it finds a solution whose SSE

 

 

 

is within TOLSSE from the SSE of the full least squares

 

 

 

problem.

 

 

MIPOPTCA

Absolute convergence tolerance for mixed-integer opti-

0.05

 

 

mization problems. This must be a nonnegative scalar.

 

 

MIPOPTCR

Relative convergence tolerance for mixed-integer optimiza-

0.0001

 

 

tion problems. This must be a nonnegative scalar.

 

 

LINEARERROR

A 0−1 indicator. If 1, a linear objective is used when

0

 

 

solving mixed-integer optimization problems; otherwise, a

 

 

 

squared error will be employed.

 

 

 

 

 

 

SIMIN

Name of input file for the simulator. ALAMO generates

input.txt

 

 

this file.

 

 

 

 

 

 

SIMOUT

Name of output file for the simulator. ALAMO expects

output.txt

 

 

the simulator to provide this file after each call.

 

 

 

 

 

 

GAMS

Complete path of GAMS executable (or name if GAMS

gams

 

 

is in the user path). On some systems, GAMS does not

 

 

 

run if there is white space in the current path. If avail-

 

 

 

able, GAMS will be used to solve continuous and discrete

 

 

 

optimization models generated by ALAMO.

 

 

 

 

 

ALAMO user manual and installation guide v. 2021.5.8

15

 

 

GAMSSOLVER

Name of preferred GAMS solver for solving ALAMO’s

BARON

 

 

 

 

 

mixed-integer quadratic subproblems. Special facilities

 

 

 

 

 

 

have been implemented in ALAMO and BARON that

 

 

 

 

 

 

make BARON the preferred selection for this option.

 

 

 

 

 

 

However, any mixed-integer quadratic programming solver

 

 

 

 

 

 

available under GAMS can be used.

 

SOLVEMIP

A 0−1 indicator. An optimizer (GAMSSOLVER) will be

0

 

 

 

 

 

used to solve ALAMO’s MIPs/MIQPs if this option is set

 

 

 

 

 

 

to 1; if set to 0, no MIP/MIQP optimizer will be used even

 

 

 

 

 

 

if one is available.

 

 

 

 

 

 

 

 

PRINT

 

TO

 

FILE

A 0−1 indicator. Output is directed to the listing file if

1

 

 

 

 

 

this option is set to 1; if set to 0, no output is sent to the

 

 

 

 

 

 

listing file.

 

PRINT

 

TO

 

SCREEN A 0−1 indicator. Output is directed to the screen if this

1

 

 

 

 

 

option is set to 1; if set to 0, no output is sent to the

 

 

 

 

 

 

screen.

 

 

 

 

FUNFORM

A positive integer to specify the format for printing basis

5

 

 

 

 

 

functions and models found by ALAMO. Fortran intrinsics

 

 

 

 

 

 

used in custom basis functions are retained in Fortran for-

 

 

 

 

 

 

mat; all other functions are translated based on the value

 

 

 

 

 

 

of FUNFORM. Possible values are 1 through 5, with the

 

 

 

 

 

 

following meaning:

 

 

 

 

 

 

1. FORTRAN format

 

 

 

 

 

 

2. GAMS format

 

 

 

 

 

 

3. BARON format

 

 

 

 

 

 

4. C format

 

 

 

 

 

 

5. Excel format

 

 

 

 

 

 

Note that a large number of digits may be printed in all

 

 

 

 

 

 

of these formats. In order to avoid problems reading these

 

 

 

 

 

 

strings into GAMS, the GAMS $offdigit option can be

 

 

 

 

 

 

used in the user’s GAMS file.

 

 

 

 

NTRANS

A nonnegative integer showing how many of the output

0

 

 

 

 

 

variables are to be obtained through transformations of

 

input/output variables. The last NTRANS of the out- put variables are obtained through algebraic transforma- tions of the input variables and/or the first NOUTPUTS- NTRANS output variables; their values should not be pro- vided in any DATA section or calculated by the simulator.

The parser is not case sensitive. For example, output variable labels Z1 and z1 are equivalent. For vector inputs, any items provided in excess of those required will be ignored. For example, if more than NINTPUTS XLABELS are provided, the extra labels are ignored.

In deciding whether to deactivate printing to the screen or file, users should consider that model coefficients are printed with two significant digits to the screen and with 23 digits to the listing file.

16

ALAMO user manual and installation guide v. 2021.5.8

 

 

If the parameter NDATA is set, then a data section must follow subsequently in the input file with precisely NDATA rows, one for each data point (pair of x and z values) specified in the following form:

BEGIN_DATA

.

.

.

END_DATA

If the parameter NPREDATA is set, then a data section must follow subsequently in the input file with precisely NPREDATA rows, each containing precisely NINPUTS values, thus corresponding to a point in the x-space, specified in the following form:

BEGIN_XPREDATA

.

.

.

END_XPREDATA

If the parameter NVALDATA is set, a similar data section must be provided using a similar construct:

BEGIN_VALDATA

.

.

.

END_VALDATA

If the parameter NCUSTOMBAS is set, user-specified basis functions must be provided using the construct:

BEGIN_CUSTOMBAS

.

.

.

END_CUSTOMBAS

where basis functions are provided one per line. The parser is not case sensitive and allows for Fortran functional expression in terms of the XLABELS. The following functions are currently accepted by the parser: addition, subtraction, multiplication, division, power (∗∗ and ^), abs, exp, log, log10, sqrt, sinh, cosh, tanh, sin, cos, tan, asin, acos, and atan. Other functions may be expressed in terms of the preceding operators and functions, e.g., min(a, b) = (a+b)/2−|a−b|/2.

If the parameters MONO, MULTI2, MULTI3, or RATIOS are set, the corresponding powers must also be specified as row vectors of corresponding length in the following way:

ALAMO user manual and installation guide v. 2021.5.8

17

 

 

Parameter Description

MONOMIALPOWERRow vector of monomial powers considered in basis func- tions; powers of 0 or 1 are not allowed. If MONO is pro-

 

vided, MONOMIALPOWER must be of length MONO.

MULTI2POWER

Row vector of powers to be considered for pairwise com-

 

binations in basis functions. If MULTI2 is provided,

 

MULTI2POWER must be of length MULTI2.

 

 

MULTI3POWER

Row vector of powers to be considered for triplet com-

 

binations in basis functions. If MULTI3 is provided,

 

MULTI3POWER must be of length MULTI3.

 

 

RATIOPOWER

Row vector of powers to be considered for ratios in basis

 

functions. If RATIOS is provided, RATIOPOWER must

 

be of length RATIOS.

The entries of the above vectors must be space separated. As stated above, the user is not obligated to specify the parameters MONO, MULTI2, MULTI3, or RATIOS. If any of the cor- responding power options are provided, ALAMO will count them and infer the total number of powers specified by the user.

If the parameter NTRANS is set to a positive entry, NTRANS functions must be provided using the construct:

BEGIN_TRANSFORMS

.

.

.

END_TRANSFORMS

where transformation functions are provided one per line. Line k of a TRANSFORMS section provides an algebraic transformation that determines transformed output k which, in turn, cor- responds to output variable NOUTPUTS-NTRANS+k. The parser is not case sensitive and allows for Fortran functional expression in terms of the XLABELS and ZLABELS. For the types of functions supported, see the discussion under BEGIN CUSTOMBAS above.

6.4Constrained regression

This section describes ALAMO’s constrained regression capabilities. There are two distinct constrained regression capabilities implemented currently in ALAMO:

•The ability to enforce constraints, such as bounds, on the response function.

•The ability to enforce combinatorial constraints on the types of basis functions utilized, including constraints on groups of basis functions.

The primary options that control application of constrained regression to ALAMO’s response function are:

18

ALAMO user manual and installation guide v. 2021.5.8

 

 

Parameter

Description

 

 

ZMIN

Minimum values for output variables. One per output

 

variable, space separated. If this vector is specified, the

 

corresponding lower bounds on output variables are en-

 

forced.

 

 

ZMAX

Maximum values for output variables. One per output

 

variable, space separated. If this vector is specified, the

 

corresponding upper bounds on output variables are en-

 

forced.

 

 

EXTRAPXMIN

Minimum values for safe extrapolation region. One per

 

input variable, space separated. If this vector is speci-

 

fied, ZMIN and ZMAX are enforced over EXTRAPXMIN

 

to (EXTRAP)XMAX; otherwise, they are enforced over

 

XMIN to (EXTRAP)XMAX.

 

 

EXTRAPXMAX

Maximum values for safe extrapolation region. One per

 

input variable, space separated. If this vector is specified,

 

ZMIN and ZMAX are enforced over (EXTRAP)XMIN to

 

EXTRAPXMAX; otherwise, they are enforced over (EX-

 

TRAP)XMIN to XMAX.

 

 

PRINTEXTRAP

A 0/1 flag to signal printing of ALAMO’s predictions in

 

the extrapolation region. By default, PRINTEXTRAP is

 

set to 0. If set to 1, ALAMO will report predicted val-

 

ues at points within the region between EXTRAPXMIN

 

to EXTRAPXMAX. The reported points will be gener-

 

ated randomly with approximately the same density as

 

that of input points within XMIN to XMAX that were

 

used by ALAMO for model determination (these points

 

include points in the user-specified preexisting data set

 

and ALAMO-selected simulation set).

 

 

Custom constrained regression, i.e., constrained regression for enforcing conditions other than simple bounds, can be done by setting the option CRNCUSTOM:

Option

Description

Default

 

 

 

CRNCUSTOM

Number of custom constraints (other than bounds). CRN-

0

 

CUSTOM must be a nonnegative integer.

 

 

 

 

If CRNCUSTOM is specified, the custom constraints themselves are described through a related section:

BEGIN_CUSTOMCON

.

.

.

END_CUSTOMCON

ALAMO user manual and installation guide v. 2021.5.8

19

 

 

where, in each of CRNCUSTOM lines of this section, one would need to specify the output variable index j associated with a custom constraint, followed by white space, followed by a function g(x, z) expressed in terms of input and output variable labels. ALAMO will then enforce the constraint g ≤ 0 when building a model for output variable j.

The following are algorithmic options that control implementation aspects of the above con- strained regression features. These options may be optionally set as follows:

Option

Description

Default

 

 

 

 

CRTOL

Tolerance within which custom constraints must be satis-

1e-3

 

fied. CRTOL must be a real that is no smaller than 1e-5.

 

 

 

Bound and custom constraints will be satisfied within an

 

 

 

absolute tolerance equal to CRTOL.

 

 

CRNINITIAL

Number of random bounding points at which constraints

0

 

 

are sampled initially. CRNINITIAL must be a nonnega-

 

 

 

tive integer.

 

 

 

 

 

 

CRMAXITER

Maximum allowed constrained regression iterations. Con-

10

 

 

straints are enforced on additional points during each it-

 

 

 

eration. CRMAXITER must be a positive integer.

 

 

 

 

 

 

CRNVIOL

Number of bounding points added per round per con-

2*NINPUTS

 

straint (bound or custom) in each iteration. CRNVIOL

 

 

 

must be a positive integer.

 

 

CRNTRIALS

Number of random trial bounding points per round of con-

100

 

 

strained regression. CRNTRIALS must be a positive in-

 

 

 

teger.

 

 

 

 

 

 

In addition to imposing constraints on the response surface it produces, ALAMO has the ability to enforce constraints on groups of selected basis functions. This can be accomplished through ALAMO’s NGROUPS option:

Option

Description

Default

 

 

 

NGROUPS

Number of groups that must be constrained. NGROUPS

0

 

must be a nonnegative integer.

 

If a positive NGROUPS is specified, the groups themselves must be specified through a related section:

BEGIN_GROUPS

.

.

.

END_GROUPS

where, in each line of this section, one would need to specify information of the form

Group-id Member-type Member-indices <Powers>

20

ALAMO user manual and installation guide v. 2021.5.8

 

 

In this construct, each group is uniquely associated with a Group-id ranging from 1 to NGROUPS. Each line must contain three required parameters (Group-id, Member-type, Member-indices); the fourth parameter (Powers) is required only in the context of basis functions that involve powers. The syntax of this section must obey the following rules:

•Each line pertains to a single group.

•A group may be described over several lines, with each line restricted to describing a single type of component of the group.

•Group-id is a nonnegative integer between 1 and NGROUPS that denotes the numerical id (index) of a group described (at least partly) in a line.

•Member-type is an attribute for the member(s) of the group described in the specific line and can take anyone of the values LIN, LOG, EXP, SIN, COS, MONO, MULTI2, MULTI3, RATIO, RBF, CUST, and CONST corresponding to different types of basis functions. In addition, Member-type may be set equal to GRP if it is desired to specify a group of groups.

•Member-indices is used to specify the composition of a group in terms of indices of input variables and groups. The keyword CONST should not be followed by any Member-indices (as there is only one constant in the model). The keywords MONO, EXP, LOG, SIN and COS must be followed by exactly one index that has a value between 1 and NINPUTS corresponding to the input variable involved in the basis function; alternatively, a value of −1 may be used to denote that all input variables should be considered (with a specific power in the case of MONO). The keywords MULTI2, MULTI3 and RATIO must be followed by two, three, and two indices, respectively, indicating the input variables involved in the corresponding basis function; alternatively, an index of −1 may be used to denote that all possible input variable combinations in any of these basis functions should be considered. The keyword LIN may be followed by as many as NINPUTS Member-indices and specifies which linear terms of the model are included in the group; alternatively, an index of −1 may be used to denote that all possible linear terms are included in the group. Similarly, the keywords CUST and RBF may be followed by as many as NCUSTOMBAS and NDATA Member-indices and an index of −1 may be used to denote all possible custom basis functions and RBFs in a group. As many as NGROUPS−1 indices may follow the keyword GRP in order to specify which groups form a group.

•When Member-type is one of MONO, MULTI2, MULTI3, or RATIO, in addition to Member-indices, the input line must specify the power(s) involved in the group; if power equals −1111, all powers are considered.

•Membership in a group is non-exclusive; a basis function or group may belong to multiple groups.

Once the number of groups has been specified and each group has been described through the GROUPS construct, group constraints can be specified through the GROUPCON section:

BEGIN_GROUPCON

.

.

.

ALAMO user manual and installation guide v. 2021.5.8

21

 

 

END_GROUPCON

ALAMO permits different group constraints to be imposed on different output variables. Each line of the GROUPCON section is dedicated to a group-output variable combination and has the following information:

Group-id Output-id Constraint-type Integer-parameter

The rules for completing this section are as follows:

•Each line describes a single group constraint.

•Group-id is a nonnegative integer between 1 and NGROUPS that denotes the numerical id (index) of the primary (and sometimes only) group involved in the constraint.

•Output-id is a nonnegative integer between 1 and NOUTPUTS for which the constraint will be imposed; a value of −1 can be used in this entry to denote that the constraint should be enforced for all output variables.

•Constraint-type is a string descriptor that can take anyone of the following values:

–NMT: to denote a no-more-than constraint, i.e., require that no more than Integer- parameter members of this group should be selected in the model.

–ATL: to denote an at-least constraint, i.e., require that at least Integer-parameter members of this group should be selected in the model.

–REQ: to require that, if the primary group is selected, then the group with id equal to Integer-parameter should also be selected.

–XCL: to require that, if the primary group is selected, then the group with id equal to Integer-parameter should not be selected.

•A group may appear in more than one constraint. This flexibility coupled with the fact that input variables and groups may belong to multiple groups allows us to enforce sparsity constraints on model attributes within groups, between groups, and groups organized in clusters, trees, or any other structure.

7ALAMO output

7.1ALAMO screen output

The screen output below is obtained for problem e1.alm.

***************************************************************************

ALAMO version 2021.5.8. Built: WIN-64 Sat May 8 17:51:31 EDT 2021

If you use this software, please cite:

22ALAMO user manual and installation guide v. 2021.5.8

Cozad, A., N. V. Sahinidis and D. C. Miller,

Automatic Learning of Algebraic Models for Optimization,

AIChE Journal, 60, 2211-2227, 2014.

ALAMO is powered by the BARON software from http://www.minlp.com/

***************************************************************************

Licensee: Nick Sahinidis at The Optimization Firm, LLC, niksah@minlp.com.

***************************************************************************

Reading input data

Checking input consistency and initializing data structures Warning: eliminating basis log(X1)

Step 0: Initializing data set

User provided an initial data set of 11 data points We will sample no more data points at this stage

***************************************************************************

Iteration 1 (Approx. elapsed time 0.16E-01 s) Step 1: Model building using BIC

Model building for variable Z

----

BIC = -0.100E+31 with Z = X1^2

Calculating quality metrics on observed data set.

Quality metrics for output Z

----------------------------

SSE OLR:

0.00

SSE:

0.00

RMSE:

0.00

R2:

1.00

R2 adjusted:

1.00

Model size:

1

BIC:

-0.100E+31

Cp:

-9.00

AICc:

-0.100E+31

HQC:

-0.100E+31

MSE:

0.00

SSEp:

0.00

RIC:

3.89

MADp:

0.00

Total

execution time 0.16E-01

s

 

Times

breakdown

 

 

 

OLR time:

0.0 s in

6

ordinary linear regression problem(s)

ALAMO user manual and installation guide v. 2021.5.8

23

 

 

 

 

 

 

 

 

MIP

time:

0.0

s

in

0

quadratic integer problem(s)

 

Simulation time:

0.0

s

to

simulate 0 point(s)

 

All

other time:

0.16E-01

s

in 1 iteration(s)

 

Normal termination

***************************************************************************

The software first reports the version, platform, and compilation date of the executable, followed by credits. Then, after reading the input data, a consistency check is run on the problem data and, if passed, the data structures are initialized. In this specific example, a warning is issued that logarithmic basis functions are not considered since the input variable is allowed to take negative values. Subsequently, information is provided for all algorithmic steps. During initialization (Step 0), it is reported that 11 data points are used for sampling and that no simulator is called in addition to using the preexisting data set. In Step 1, the model is built in stages. Earlier in the search, the perfect model z = x2 is identified. Since there is no simulator provided, there is no adaptive sampling and execution terminates here after reporting a detailed breakdown of CPU times for the different algorithmic steps, including the number of calls to the optimizer (0 in this example) and the simulator (0 in this example). There are no calls to an optimizer in this example because the problem is small enough to be solved faster by complete enumeration.

8Termination conditions and error messages

Errors in the input file are reported on the screen and/or the listing file in the form of “warnings” and “errors.” ALAMO attempts to continue execution despite warnings. If the errors are severe, the program execution is stopped and the line where the fatal error occurred is displayed. The input file should be checked even if the warnings are not severe, as the problem might have been parsed in a way other than it was intended to be. Detailed error messages are provided in that case.

If execution terminates normally, ALAMO prints ‘Normal termination.’ If there is an error, the message on the screen or file is ‘ALAMO terminated with termination code,’ followed by one of the following error codes, all of which are self-explanatory:

1.ALAMO must be called with one or two command line arguments.

2.ALAMO input file name must be no longer than 1000 characters.

3.ALAMO input file not found.

4.ALAMO input file cannot be opened.

5.Keyword not recognized in input file.

6.Keyword too long in input file.

7.Incomplete input file.

8.Input value in error in input file.

24

ALAMO user manual and installation guide v. 2021.5.8

 

 

9.Number of input variables (NINPUT) must be specified before specifying XMIN values.

10.Number of input variables (NINPUT) must be specified before specifying XMAX values.

11.Number of input variables (NINPUT) must be specified before specifying XFACTOR val- ues.

12.Number of input variables (NINPUT) must be specified before specifying XLABELS.

13.Number of output variables (NOUTPUT) must be specified before specifying ZLABELS.

14.MONOMIALPOWER values have been set already. Multiple declarations are not allowed.

15.Number of input variables (NINPUT) must be specified before the DATA section of the input file.

16.Number of output variables (NOUTPUT) must be specified before the DATA section of the input file.

17.Number of data points (NDATA) must be specified before the DATA section of the input file.

18.Number of input variables (NINPUT) must be specified before the XDATA section of the input file.

19.Number of data points (NDATA) must be specified before the XDATA section of the input file.

20.Number of output variables (NOUTPUT) must be specified before the ZDATA section of the input file.

21.Number of data points (NDATA) must be specified before the ZDATA section of the input file.

22.Input data file missing required keyword(s).

23.END DATA missing or incomplete DATA section.

24.END XDATA missing or incomplete XDATA section.

25.END ZDATA missing or incomplete ZDATA section.

26.Only one of XDATA and DATA sections is allowed.

27.Only one of ZDATA and DATA sections is allowed.

28.MULTI2POWER values have been set already. Multiple declarations are not allowed.

29.MULTI3POWER values have been set already. Multiple declarations are not allowed.

30.Unable to open output file.

31.Maximum number of iterations reached.

ALAMO user manual and installation guide v. 2021.5.8

25

 

 

32.RATIOPOWER values have been set already. Multiple declarations are not allowed.

33.Error while trying to use the optimizer to solve the MIP for best subset.

34.Error while attempting to access the ALAMO execution directory.

35.Error while attempting to access the ALAMO scratch directory.

36.Error while attempting to access the external simulator.

37.Error while attempting to write the external simulator input file.

38.Error while attempting to read the external simulator output file.

39.Scaling by zero is not allowed.

40.XMAX−XMIN for all input variables must be positive.

41.XDATA must be in the range [XMIN, XMAX].

42.Simulator should not return NaN for input variable values.

43.Simulator should not return NaN for output variable values. For any variable that the simulator cannot compute, return the value of PRESET.

44.Input file is missing XMIN values.

45.Input file is missing XMAX values.

46.MONOMIALPOWERS must be specified if MONO is used.

47.MULTI2POWER must be specified if MULTI2 is used.

48.MULTI3POWER must be specified if MULTI3 is used.

49.RATIOPOWER must be specified if RATIOS is used.

50.DATA section must be specified when NDATA is nonzero.

51.Insufficient memory to allocate data structures.

52.Number of validation data points (NVALDATA) must be specified before the VALDATA section of the input file.

53.VALDATA section must be specified when NVALDATA is nonzero.

54.VALDATA section must be specified when NVALSECTIONS is nonzero.

55.Premature end of input file.

56.Number of custom constraints (CRNCUSTOM) must be specified before specifying CUS- TOMCON section.

57.END ZMIN missing or incomplete ZMIN section.

26

ALAMO user manual and installation guide v. 2021.5.8

 

 

58.END ZMAX missing or incomplete ZMAX section.

59.Number of input variables (NINPUT) must be specified before specifying EXTRAPXMIN values.

60.Number of input variables (NINPUT) must be specified before specifying EXTRAPXMAX values.

61.END CUSTOMCON missing or incomplete CUSTOMCON section.

62.Number of output variables (NOUTPUT) must be specified before specifying ZMIN values.

63.Unable to open trace file TRACEFNAME.

64.No keyword may be specified more than once.

65.Variable index is out of range.

66.Error while trying to run SNOBFIT.

67.Error while trying to solve ordinary least squares regression subproblem with the optimizer.

68.Maximum CPU time (MAXTIME) exceeded.

69.Error while trying to write in the ALAMO scratch directory.

70.Number of output variables (NOUTPUT) must be specified before specifying TOLMEAN- ERROR values.

71.A least squares subproblem failed during enumeration and no optimizer is available.

72.Licensing error. A valid license is required in order to run this software.

73.Error while trying to use the optimizer to solve the constrained regression model.

74.Error while trying to copy file to disk.

75.CUSTOMCON section must be specified when CRNCUSTOM is nonzero.

76.All output variables ignored by user. No point in calling ALAMO.

77.END CUSTOMBAS missing or incomplete CUSTOMBAS section.

78.Number of custom basis functions (NCUSTOMBAS) must be specified before the CUS- TOMBAS section of the input file.

79.Syntax error in custom basis function.

80.All variable labels must begin with an alphabetical character (A-Z or a-z).

81.Variable labels may only contain alphanumerical characters (A-Z, a-z, 0-9) or underscores.

82.All variable labels must be distinct.

83.All CRCUSTOMIND values must range from 1 to NOUTPUTS.

ALAMO user manual and installation guide v. 2021.5.8

27

 

 

84.Each custom constraint must be expressed in terms of the labels of input variables and a single output variable.

85.Each line of the input file must contain no more than 10000 characters. Longer data records may be split into multiple lines using & at the end of a line to signify continuation of the record in the next line.

86.Syntax error in input file.

87.Inline comments must be preceded by ! or #.

88.Inconsistent use of NDATA and INITIALPOINTS.

89.A least squares subproblem failed during model buildup and no optimizer is available.

90.Number of output variables (NOUTPUT) must be specified before specifying MAXTERMS values.

91.Number of output variables (NOUTPUT) must be specified before specifying TOLREL- METRIC values.

92.Number of output variables (NOUTPUT) must be specified before specifying TOLABS- METRIC values.

93.END TRANSFORMS missing or incomplete TRANSFORMS section.

94.Number of transformed output variables (NTRANS) must be specified before the TRANS- FORMS section of the input file.

95.Syntax error in output transformation function.

96.Number of transformed output variables (NTRANS) cannot exceed total number of outputs (NOUTPUTS).

97.Number of transformed output variables (NTRANS) must be specified after specifying total number of outputs (NOUTPUTS).

98.Number of transformed output variables (NTRANS) must be specified before providing output data section (DATA or ZDATA).

99.Number of output variables (NOUTPUT) must be specified before specifying ZISINT val- ues.

100.Number of prediction points (NPREDATA) must be specified before the PREDATA section of the input file.

101.END XPREDATA missing or incomplete XPREDATA section.

102.Number of input variables (NINPUT) must be specified before the XPREDATA section of the input file.

103.XPREDATA section must be specified when NPREDATA is nonzero.

28

ALAMO user manual and installation guide v. 2021.5.8

 

 

104.A GROUPS section is allowed only if NGROUPS is positive.

105.A GROUPS section is allowed only after NINPUTS has been defined.

106.A GROUPS section is allowed only after NOUTPUTS has been defined.

107.A GROUPS section is allowed only after NDATA has been defined.

108.Group-ids must be integers between 1 and NGROUPS.

109.Member-type must be one of LIN, LOG, EXP, SIN, COS, MONO, MULTI2, MULTI3, RATIO, RBF, CUST, and CONST.

110.All powers in group definitions must appear in user-specified basis functions.

111.NGROUPS has been specified but a smaller number of groups has been described in the GROUPS section or the GROUPS section is entirely missing.

112.A GROUPCON section is allowed only if NGROUPS is positive.

113.A GROUPCON section is allowed only after NOUTPUTS has been defined.

114.Member-indices for input variables must be integers between 1 and NINPUTS.

115.Member-indices for radial basis functions must be integers between 1 and number of data points (NDATA).

116.Member-indices for custom basis functions must be integers between 1 and NCUSTOMBAS.

117.Member-indices for groups must be integers between 1 and NGROUPS.

118.Output variable indices must be integers between 1 and NOUTPUTS.

119.Constraint-type must be one of NMT, ATL, REQ, and XCL.

120.Integer-parameters for REQ and XCL group constraints must be integers between 1 and

NGROUPS.

121.Number of input variables (NINPUT) must be specified before specifying EXCLUDE val- ues.

122.Number of output variables (NOUTPUT) must be specified before specifying IGNORE values.

123.Unable to find the external simulator.

124.Simulator failed MAXSIM times.

125.TRANSFORMS section must be specified when NTRANS is nonzero.

126.Evaluation error with transformation function. Try a different transformation.

127.Error while trying to write file to disk.

ALAMO user manual and installation guide v. 2021.5.8

29

 

 

128.Number of output variables (NOUTPUT) must be specified before specifying ZMAX values.

129.Powers for polynomial basis functions have been set already. Multiple declarations are not allowed.

130.Number of input variables (NINPUT) must be specified before specifying XISINT values.

131.Number of output variables (NOUTPUT) must be specified before specifying TOLMAX- ERROR values.

132.A MIP solver is required to proceed with the current set of options but one is not avail- ablefound.

9Compatibility with previous versions of ALAMO

Starting with ALAMO v. 2013.10.0, the input format was changed. Input requirements of earlier versions were maintained with two exceptions:

•Previous versions required that ALAMO options be specified in a separate file than preex- isting data. All ALAMO input must now be entered in a single file.

•Preexisting data can now be entered in a format that combines input and output measure- ments in a column wise fashion.

For compatibility with early versions of ALAMO, the following keywords are also acceptable in ALAMO v. 2013.10.0 and beyond:

Parameter

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INITIALPOINTS

Number of data points in the initial sample set. This pa-

 

 

 

rameter represents the sum of NDATA and NSAMPLE.

 

 

 

INITIALPOINTS must be a nonnegative integer. If de-

 

 

 

clared, INITIALPOINTS must be greater than or equal to

 

 

 

NDATA. If INITIALPOINTS is declared, NSAMPLE will

 

 

 

be ignored and set equal to the difference of INITIAL-

 

 

 

POINTS and NDATA; otherwise, INITIALPOINTS will

 

 

 

be set equal to the sum of NDATA and NSAMPLE.

NVARS

This is equivalent to NINPUTS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BEGIN

 

XDATA

Can be used in conjunction with BEGIN

 

ZDATA to pass

 

 

 

x-values separately from z-values. Only one of BE-

 

 

 

GIN

 

 

XDATA and BEGIN

 

 

DATA is permitted.

 

 

 

 

 

 

 

BEGIN

 

ZDATA

Can be used in conjunction with BEGIN

 

XDATA to

 

 

 

pass x-values separately from z-values. Only one of BE-

 

 

 

GIN

 

ZDATA and BEGIN

 

DATA is permitted.

 

 

CONREG

It used to serve as an indication that constrained regres-

 

 

 

sion will be invoked. This is now ignored and the need for

 

 

 

constrained regression is inferred from other options.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

ALAMO user manual and installation guide v. 2021.5.8

 

 

Starting with ALAMO v. 2019.7.30, the keyword REGULARIZER was replaced by the more appropriate SCREENER. The keyword REGULARIZER is still acceptable and the possible values of SCREENER are backwards compatible with those of REGULARIZER.

10 Bibliography

The following is a partial list of ALAMO-related publications that describe the algorithms im- plemented in the software, the theory behind them, and some related applications.

1.A. Cozad, N. V. Sahinidis, and D. C. Miller. Learning surrogate models for simulation- based optimization. AIChE Journal, 60, 2211–2227, 2014.

2.A. Cozad, N. V. Sahinidis, and D. C. Miller. A combined first-principles and data-driven approach to model building. Computers & Chemical Engineering, 73, 116–127, 2015.

3.Z. T. Wilson and N. V. Sahinidis. The ALAMO approach to machine learning. Computers & Chemical Engineering, 106, 785-795, 2017.

4.K. Lindqvist, Z. T. Wilson, E. Næss and N. V. Sahinidis. A machine learning approach to correlation development applied to fin-tube bundle heat exchangers Energies, 11(12), 3450, 2018.

5.Z. Wilson and N. V. Sahinidis. Automated learning of chemical reaction networks. Com- puters & Chemical Engineering, 127, 88-98, 2019.